Deep cylcle electric forklift lithium battery for rail inspection robot/commercial delivery robot

Short Description:

Compact and lightweight

A LFP battery of the same model is about 2/3 the volume and 1/3 the weight of a lead-acid battery


Product Detail

Product Tags

The following are the specifications and detailed parameters of the LFP CELL

Specifications

1629447220(1)

Parameters

1. Long cycle life

10 times longer than SLA battery, which bring more value.

2. High reliability

Lithium ion phosphate batteries are safer than other kinds of lithium ion batteries, The LiFePo4 could decrease the risk of fire and explosion as much as possible because of excellent material characteristic.

3. Good electrical performance

LFP battery can support high discharge rate and fast charging.

4. Compact and lightweight

A LFP battery of the same model is about 2/3 the volume and 1/3 the weight of a lead-acid battery.

5. Environment friendly

It does not contain any heavy metals and rare metals, non-toxic, pollution-free.

6dfad673d1c8c8ceb2df6a2e9971bc3
d823e1359821734022c7109e08f309a
10c21c61399a36deb2148b41af88e23

Application

1.Medical disinfection robot
2.Rail inspection robot
3.Commercial delivery robot
4.Jacking up handling robot
5.Handling logistics forklift
6.Small size forklift
7.Elevator
8.Heavy load handling robot

1630055044(1)
1630055056(1)

1 Battery Usages

1.1 Charge
Charging terminal of battery is connected to charger appropriate with it, and then charge. Charging voltage is 28.8±0. 15V. Do not reverse.

1.2 Discharge
Note that the positive and negative9(poles are not reversed as indicated by the battery case logo), then connect to the matching load.

2 Battery Test
Single cell and Protection board specification are only results of standard test, this is for reference.

2. 1 Standard Test Requirements
Battery tested must be done within 1 month after production. If the battery is not tested on time due to transportation or other reasons, the battery can be recharged and discharged for testing.
All tests in this specification should be done in standard atmospheric conditions. (Temperature: 25± 2℃; relative humidity: 65± 20%).
Standard charge voltage is 28.8±0. 15V, standard discharge cutoff voltage is about 20.0V; standard current is I5 (when I5 > the normal work current, test according to the normal current).

2.2 Standard Charge
Charge the battery with Lithium ion battery special test cabinet, with standard charging voltage, standard current, constant current and constant voltage charging to the current dropping to 0.05 I5·

2.3 Standard Discharge
Discharge the battery with Lithium ion battery special test cabinet, discharge to standard discharge cutoff voltage with standard current, constant discharging or until the battery stops.